3.  Arming the Control Panel     
3.1  Away Arming           
3.1.1  How to Away Arm                
 
[#] [USER CODE] (Leave via Entry/Exit Zone) 
 
1.  Ensure that the LCD display reads „Ready to Arm‟ alongside the partition number being armed. If 
not, check that all protected doors and windows are closed and that all movement has ceased in 
areas covered by motion detectors. If necessary, bypass any required zones and close the front 
door. 
2.  Press the [#] key. 
3.  Enter a valid [USER CODE]. If an incorrect code is  entered, the keypad buzzer will beep three 
times. In the event of an error, press the [#] key and re-enter the code. 
4.  The ARM LED will come on and the keypad buzzer will sound for the duration of the exit delay. 
The LCD  display will read „Exit Delay‟ alongside the partition  number that  is being armed. Any 
bypassed zones  will be displayed on  the  LCD display as  solid text. Any violated  zones  will  be 
displayed  on  the  LCD  display  as  flashing  text.  To  scroll  through  zones  which  have  been 
bypassed or violated use the [PANIC] and [MED] keys. 
5.  Leave only via a designated exit route. The panel will away arm at the end of the exit delay, if any 
enter/exit zone is violated, e.g. the front door. 
6.  Once  the  panel has  armed,  the LCD  display will  read  „Armed‟ alongside the  partition that  has 
been armed. 
3.1.2  Quick Away Arm - Shortcut Key     
 
(Hold down the [1] key until the keypad buzzer sounds) 
 
If  this  function  is  enabled,  it  is  possible  to  AWAY  arm  by  simply  holding  down  the  [1]  key.  The  LCD 
display will read „Exit Delay‟ alongside the partition number being armed. The keypad buzzer sounds and 
the arming process begins. 
 
NOTE:    
If  the  partition  is  already  STAY  armed,  this  key  will  initialize  AWAY  arming.  It  is  therefore  possible  to 
change directly from STAY armed to AWAY armed. 
3.2  Stay Arming          
 
Stay arming allows the user to monitor selected perimeter zones and bypass interior zones. The user can 
remain on the premises with access to designated areas during the STAY ARM cycle. Any zone that may 
be violated accidentally should be programmed as a buzz zone. When violated, a buzz zone will cause 
the keypad buzzer to sound for 30 seconds before sounding the siren. Entering a valid user code before 
the siren sounds, prevents an alarm condition from being registered and will silence the keypad buzzer 
and prevent the siren from sounding.