IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
Enable Automatic Re-enabling of Shutdown Zones at the Time of the Dialler test
Disable Automatic Re-enabling of Shutdown Zones at the Time of the Dialler test
Enable Bypassing of Common Zones
Disable Bypassing of Common Zones
Enable Delay Before Communications
Disable Delay Before Communications
Enable Silent Keypad Panic
Disable Silent Keypad Panic
Default values are shaded
Exit Delay Period (default = 0030 i.e. 30 seconds)
[#] [INSTALLER CODE] [*] [2] [3] [0] [*] [PARTITION NUMBER] [*] [MMSS] [*]
Partition number = 1 – 8
MMSS = 00m00s – 59m59s
Primary Entry Delay Period (default = 0030 i.e. 30 seconds)
[#] [INSTALLER CODE] [*] [2] [3] [1] [*] [PARTITION NUMBER] [*] [MMSS] [*]
Partition number = 1 – 8
MMSS = 00m00s – 59m59s
Secondary Entry Delay Period (default = 0030 i.e. 30 seconds)
[#] [INSTALLER CODE] [*] [2] [3] [2] [*] [PARTITION NUMBER] [*] [MMSS] [*]
Partition number = 1 – 8
MMSS = 00m00s – 59m59s
Keypad Partition (default = Partition 1)
[#] [INSTALLER CODE] [*] [2] [4] [0] [*] [KEYPAD NUMBER] [*] [PARTITION NUMBER] [*]
Keypad number = 1 – 8
Partition number = 1 – 8
Keypad Display Start Zone (default = Zone 1)
[#] [INSTALLER CODE] [*] [2] [4] [1] [*] [KEYPAD NUMBER] [*] [START ZONE] [*]
Keypad number = 1 – 8
Start zone = 01 – 64