IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
Week of Month to End Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [3] [0] [*] [WEEK] [*]
Week = 1 – 5
Daylight Saving Time Offset (default = 60)
[#] [INSTALLER CODE] [*] [3] [1] [*] [DAYLIGHT SAVING TIME OFFSET] [*]
Daylight saving time = 0 – 250
Auto Test Report Interval (default = 1)
[#] [INSTALLER CODE] [*] [3] [2] [*] [AUTO TEST REPORT INTERVAL] [*]
Auto test interval = 0 – 15
Auto Test Time (default = 0010)
[#] [INSTALLER CODE] [*] [3] [3] [*] [HHMM] [*]
HHMM = 00h00m – 23h59m
Download Code Default Disable (default = 0)
[#] [INSTALLER CODE] [*] [3] [4] [*] [DOWNLOAD CODE DEFAULT DISABLE] [*]
Download code default disable = 0 or 10
Hardware Default Switch Disable (default = 0)
[#] [INSTALLER CODE] [*] [3] [5] [*] [HARDWARE DEFAULT SWITCH DISABLE] [*]
Reset switch disable = 0 or 10
Telephone Number 1 Communications Format (default = 5)
[#] [INSTALLER CODE] [*] [4] [1] [*] [TELEPHONE NO. 1 COMMUNICATIONS FORMAT] [*]
1.8kHz TX, 2.3kHz HS, 40PPS
1.8kHz TX, 2.3kHz HS, 20PPS
Telephone No. 1 Communications Format = 0 – 8