IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
5
LOCATION 10
Zone Shutdown Count (default = 5)
[#] [INSTALLER CODE] [*] [1] [0] [*] [ZONE SHUTDOWN COUNT] [*]
Zone shutdown count = 1 15
LOCATION 11
Programmable Zone Loop Response Time (default = 2)
[#] [INSTALLER CODE] [*] [1] [1] [*] [ZONE LOOP RESPONSE TIME] [*]
Zone loop response time = 1 255
LOCATION 12
Cross-zone Delay Time (default = 0030)
[#] [INSTALLER CODE] [*] [1] [2] [*] [MMSS] [*]
MMSS = 00m00s 59m59s
LOCATION 13
Cross-zone Count (default = 3)
[#] [INSTALLER CODE] [*] [1] [3] [*] [CROSS-ZONE COUNT] [*]
Cross zone count = 1 15, with 0 to disable