IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
8
LOCATION 21
Keypad Lockout Time (default = 0030)
[#] [INSTALLER CODE] [*] [2] [1] [*] [MMSS] [*]
MMSS = 00m01s 59m59s
LOCATION 22
Keypad Sleep Delay (default = 0500)
[#] [INSTALLER CODE] [*] [2] [2] [*] [MMSS] [*]
MMSS = 00m01s 59m59s
LOCATION 23
User, Installer & Maintenance Code - Number of Digits (default = 4)
[#] [INSTALLER CODE] [*] [2] [3] [*] [NUMBER OF DIGITS] [*]
Number of digits = 4 or 6
LOCATION 24
Number of Account Code Digits (default = 4)
[#] [INSTALLER CODE] [*] [2] [4] [*] [NUMBER OF DIGITS] [*]
Number of digits = 4 or 6
LOCATION 25
Month to Start Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [2] [5] [*] [MONTH] [*]
Month = 1 12, with 0 to disable
LOCATION 26
Day of Week to Start Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [2] [6] [*] [DAY] [*]
Day = 1 7
LOCATION 27
Week of Month to Start Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [2] [7] [*] [WEEK] [*]
Week = 1 5
LOCATION 28
Month to End Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [2] [8] [*] [MONTH] [*]
Month = 1 12, with 0 to disable
LOCATION 29
Day of Week to End Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [2] [9] [*] [DAY] [*]
Day = 1 7