IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
18
Sub-location 3 is Bus-wired Peripheral Fail
Sub-location 4 is Box Tamper
Sub-location 5 is Dedicated Panic
Sub-location 6 is Reserved
Sub-location 7 is Telephone Line Tamper
Sub-location 8 is Telephone Line Restore
Reporting code = 01 FF, with 00 to disable
LOCATION 303
Global Reporting Code 4
[#] [INSTALLER CODE] [*] [3] [0] [3] [*] [SUB-LOCATION] [*] [REPORTING CODE] [*]
Sub-location = 1 8
Sub-location 1 is Wired Zone Expander Low Power Supply Monitoring
Sub-location 2 is Wired Zone Expander Low Power Supply Restore
Sub-location 3 is Reserved
Sub-location 4 is Reserved
Sub-location 5 is Reserved
Sub-location 6 is Reserved
Sub-location 7 is Reserved
Sub-location 8 is Reserved
Reporting code = 01 FF, with 00 to disable
LOCATIONS 304 - 307
Zone Alarm Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 304 307
Zone Number = 01 64
Reporting code = 01 FF, with 00 to disable
LOCATIONS 308 - 311
Zone Alarm Restoral Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 308 311
Zone Number = 01 64
Reporting code = 01 FF, with 00 to disable
LOCATIONS 312 - 315
Zone Tamper Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 312 315
Zone Number = 01 64
Reporting code = 01 FF, with 00 to disable
LOCATIONS 316 - 319
Zone Tamper Restore Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 316 319
Zone Number = 01 64

Table of Contents

Other manuals for IDS X64

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS X64 and is the answer not in the manual?

IDS X64 Specifications

General IconGeneral
Keypads8
Stay/Away ArmingYes
Tamper ProtectionYes
Operating SystemProprietary
Supported ProtocolsContact ID, SIA
Power Supply16.5VAC
Backup Battery12VDC 7Ah
AlertsSMS
RAMUnknown

Related product manuals