EasyManua.ls Logo

IDTECK FGR006 - RS232 Communication Port Connection; RS485 Communication Port Connection

IDTECK FGR006
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
101-091 14
FGR006 – Version 3.0
IDTeck
FGR006 FINGERPRINT & PROXIMITY READER
5.2 RS232 Communication Port Connection
You set the jumper with a silkscreen side up.
9-pin connector (COM Port, D-SUB 9P Female) is required to connect serial communication RS-232 between
Main Unit and PC (Personal Computer)
- Connect RS232 TX, Yellow wire of Main Unit to pin number 2 of 9-pin connector.
- Connect RS232 Rx, Grey wire of Main Unit to pin number 3 of 9-pin connector.
- Connect GND, Black wire of Main Unit to pin number 5 of 9-pin connector.
- Plug in 9-pin connector to COM1 or COM2 Port of PC
- Install and run Application Software.
5.3 RS485 Communication Port Connection
You set the jumper with a silkscreen side up.
RS-485/RS-232 converter is required to connect serial communication RS485 between Main Unit and PC
(Personal Computer). The converter used CNP200A.
- Connect RS485 A, Grey wire of Main Unit to Red wire of CNP200A converter.
- Connect RS485 B, Yellow wire of Main Unit to Grey wire of CNP200A converter.
- Plug in RS232 9-pin connector of CNP200A converter to COM1 or COM2 Port of PC.
- Install and run application software.
FGR006 (FGR006EX) Wire P C (D-SUB 9P Female)
YELLOW RS232 TX 2 RS232 Rx
GRAY RS232 Rx 3 RS232 TX
BLACK GND 5 GND
FGR006 (FGR006EX) Wire CNP-200A Converter Wire
GREY RS485-A RED RS485-A
YELLOW RS485-B GREY RS485-B