14
ACCURA9/9L INSTRUCTION MANUAL
Remote mode
Enter into Remote Mode with
REMOTE key.
Remotemode
*** Auto Shot EXT
Ch 00 St 00.100
Sp 100.0 Sc 000300
Cm LE VC
Dispensing is operated by external signal at Remote
Mode. In order to meet the user’s requirement,
Foot switch (FSW), Exit I/O (Exit) and RS232C(RS2) can be used
for dispensing. Every time on entry of Remote key, FWS, EXT
and RS2 are shown.
※
When only foot switch is used, it can be shifted to input through LCD panel by
pressing SHIFT+REMOTE key.
※
Refer to 10 “Remote Mode” in the instruction manual for details.
End AUTO mode
To end AUTO mode, enter H+MODE keys except when REMOTE Mode.