ACCURA9/9L INSTRUCTION MANUAL
10.2.2 Output Signal
Power-on Signal
(I/O PORT2 5PIN)
5PIN Output Condition
1
Output after switching on.
0
Output after switching off.
AUTO SIGNAL
(I/O PORT2 23PIN)
23PIN OUTPUT CONDITION
1
Output at the time of Auto Mode.
0
Output at the time except on Auto Mode.
STEADY MODE
(I/O PORT2 4PIN)
4PIN OUTPUT CONDITION
1
Output at the time of Steady Mode.
0
Output at the time except on Steady Mode.
BUSY SIGNAL (I/O PORT2 24PIN)
24PIN OUTPUT CONDITION
0
Output when the controller is available to accept Input signal.
1
Output (*1) when the controller is unavailable to accept Input
signal with exceptions of follows: 1. Available to accept only ’0’
signal during dispensing in Steady Mode. 2. Available to accept
only ‘Shot-Off’ signal during dispensing in Auto Mode.
(※1)
During dispensing (incl. vacuum time and shot time) and changing channel.
Remark
:
There might is time lag in a few metric-seconds to turn ‘1’ on the busy signal after
being accepted the input signal by the dispenser controller.
Pay attention when checking BUSY signal.