5 - ADJUSTMENTS AND SETTING-UP MASTER 880MP E-volution
GB
5 - Pag. 7 / 14
Turn the screw counter-
clockwise to move the feeder
body backwards.
Remove the oil recovery device
(C) and nose (D).
Lower the (G) spring and remove
the (F) cover, open the two
half-bushings fully by turning the
(E) shaft manually and remove
the lower half-bushing.
Close the upper half-bushing by
turning the shaft again then
replace it.
Turn the shaft and fit the lower
half-bushing.
Fully close the half bushes and
install the cover.