SWIFT K11-EN, Rev.A 43
Pulling standby
It designates time period from the last of optical fiber
advance amount to the beginning of pulling.
Pulling speed
It sets optical fibers pulling speed.
Pulling length
It sets optical fibers pulling time.
Editable
Minimum loss
It is the sum of initially measured splice loss value and the
increased loss. When splicing a special optical fiber or other
optical fibers, high loss may be incurred in spite of the
optimum discharge conditions. To match the estimated splice
loss and the actual splice loss, the minimum value of actual
splice loss should be set.
MFD Left
mode field diameter Left
MFD Right
mode field diameter Right
6.1.5 Selection
Touch SELECT icon and the selected splice mode is saved on memory and it is used upon splicing.
6.1.6 Close
Touch CANCEL icon or press and it goes back to the previous stage.