2
Installation operations SOLAR
HEATING SYSTEM COUPLING
KIT.
- Close the cold water inlet upstream
of the system and empty the storage
tank / cylinder.
- Disconnect power supply.
- Assemble the plate heat exchanger (2)
to the solar unit (1) by hanging it in
the appropriate seat and securing it
with the supplied screw (3), (Fig. 21).
- Couple the solar unit (1) to the hy-
dronic unit (c) by hanging it to the
two appropriate seats, then secure it
with the supplied screws (3), (Fig. 22).
- Make the hydraulic connections of
the kit (Fig. 23).
- Remove the two caps present on
the storage tank / cylinder to make
the connections of the relative pipes
(UCS and EFS).
- Connect the interception cock (6)
on the plate heat exchanger by inter-
posing the relative at gasket / seal.
- Following the sequence below,
connect all the pipes taking care to
interpose the at gaskets present in
the kit, pipe RP (long) - MP (long)
- UCS - RP (short) - EFS.
21
22
- Connect the two solar system pipes to
the specially arranged ttings, using
one of the pre-cut slots (L).
- Fit the tting of the safety valve. Con-
nect the silicone pipe (5) to the tting
and insert it in the can (7).
- Insert the solar storage tank / cylinder
probe (4 Fig. 23) in the appropriate
seat.
- Re-open the cold water inlet and
power supply the system again.