7. Reattach all the cables.
8. For single controller models or when replacing both controllers
simultaneously, power up the system. Check system message on the LCD
screen, SANWatch, or firmware menu-driven utility. When the replacement
controller is successfully brought online, the
Power On Status LEDs should turn
on properly.
9. For single controller models or replacing both controllers simultaneously,
Restoring NVRAM data. To restore previous ID/LUN mapping settings, users
may use the following options:
Use the “Restore NVRAM from Disks “or “Restore NVRAM from
Files” functions in the firmware. ID/LUN mapping will be restored.