Programming the SmartLink-GP 35
Programming manual
• Send SMS text message
• Send Contact ID report
• Send voice message
• Activate/Deactivate outputs
• Constraint and commands
The SmartLink-GP manages four status-change events per IN&OUT input
(i.e. 20 events) and other pre-set events generated by SmartLink-GP.
Note: Among such events are trouble restoral events such as:
Low battery restored. Bistable outputs toggled to ON
status by an event must be restored to OFF status, for
example Low battery. Or use the Simplified
management option. See “paragraph 3.7 Programming
the Inputs and Outputs — IN&OUT”.
Calls triggered by internal events will take priority over any calls sent
through the SmartLink by the device on terminals 13 and 14. Therefore,
calls coming from the device concerned will be interrupted automatically, if a
dialer-trigger event occurs (Voice, SMS or Contact ID. If several events occur
at almost the same time, SmartLink-GP will create a Call queue and will deal
with the calls in chronological order.
For example, an input short-circuit event can be programmed to activate an
output which will act on the shorted device. Or, an Incoming black list
number event can be programmed to send a voice message.
Parameter Description
No. Event number
Description Event description
Intrusion input
logic status
Enabled when SmartLink-GP is used as an Intrusion
control panel. This shows the statuses (Standby, Alarm,
Short-circuit and Tamper) the input manages in
accordance with the balance type selected in the
Inputs/Outputs table.
Save event If selected, the event concerned will be saved to the
SmartLink-GP event log with the respective date, time
and description. The log stores 32 events. Once the log
is full, new events will automatically overwrite the
oldest events in the log. The stored events are available
for viewing in the Log table, and can be viewed
separately from the other parameters. See paragraph
3.3.6 Viewing the Events log.