46 Programming the SmartLink-GP
Programming manual
3.12.5 Activating an Output
<User Code> <OutputDescription_x> ON
<User Code> <OutputDescription_y> OFF
Example
“0001 CourtesyLights ON”
Attention: Use the correct format (uppercase/lowercase/
space) for the output description. If the activated
output is a monostable output, the 'ON' command
will initialize a normal monostable cycle.
If the output has been programmed, in the Inputs/Outputs table, to
provide a feedback reply, SmartLink-GP will send an SMS text or ring as
required. See paragraph 3.7 Programming the Inputs and Outputs —
IN&OUT.
If a feedback reply is required, the message will read: "CourtesyLights OK”
3.12.6 Activating the on-board buzzer
<UserCode> BEEP x
<UserCode> BEEP
X represents the duration in seconds of the on-board buzzer signal (from 1 to
7). If x is omitted or the format is incorrect, the buzzer will emit 3 beeps at
one second intervals.
Example
“0001 BEEP 5”
If the output has been programmed, in the Inputs/Outputs table, to
provide a feedback signal, SmartLink-GP will send an SMS text or ring as
required. See paragraph 3.7 Programming the Inputs and Outputs —
IN&OUT.
If an SMS feedback reply is required, the message will read: “BEEP OK”
3.12.7 SmartLink-GP status enquiry
<UserCode> STATUS
SmartLink-GP will answer this message with the respective information:
Inputs status
Land line (PSTN) status
GSM network status
Battery status
On/Off Status
SIM credit balance
Example of status enquiry:
“0001 STATUS”