Programming the SmartLink-GP 51
Programming manual
3.13.5 Write/Change SMS message
SL MS<SMSnum> <SMSText>
Example
“SL MS7 Warning detector tamper”
Note: Refer to paragraph 3.5.2 Setting up the SMS dialler
messages for the parameter descriptions.
3.13.6 Setting the generic parameters
SL PAR <PSTNdown>,<CallAllVoice>,<Tonecheck>,<RemoveDigits>,
<AddAreaCode>,<InstallerCode>,<EnablePSTNanswerphone>,
<EnableGSManswerphone>, <DoubleCall>,<NumberofRings>
Example
“SL PAR 1,0,1,4,0735,2273,1,0,1,4”
PSTNConstraint 0= the event signals will be forwarded through
the channel currently in use
1= switches event signals to the PSTN network
GSMConstraint 0= the event signals will be forwarded through
the channel currently in use
1= switches the event signals to the GSM network
ClearCallQueue 0= the event will not effect the calls in the queue
1= the event will clear the call queu
Parameter Description
SMSnum From 1 to 10.
SMSText SMS messages from 1 to 5 accept a maximum of
80 characters, the remaining messages accept 40
characters.
Parameter Description
PSTNdown Enables PSTN line-down signslling
CallAllVoice Calls all voice dialler numbers
Parameter Description