Revision 4.02 June. 2000 11
L MODULE PCB
LED13 & LED14 (L1 & L2)
FAULT LED
DIAGNOSTICS
See table on page 9.
LK10
LAN Termination.
F2, F3 & F5
Fuses for Siren 1, Siren 2 & Detector Power.
2 Amp. M205.
LED15 & LED 16 (RX & TX)
LAN Activity LEDs
Rx =Receive Data
Tx =Send Data
T10
Cabinet Tamper input.
T8
Detector Power connections.
LK2
Memory chip (RAM) size select.
2-3 28 Pin (32k)
1-2 32 Pin (128k & 512k)
JUMPER LINK
ORIENTATION
1• 12
2 123 3• 4
3 ••• 5••6
LK3
Installer Code Default
LK4
Initilize RAM (Continue).
CAUTION.
LK6
Microprocessor select.
F4
LAN “POS” Fuse. 2Amp. M205.
T6
Auxiliary outputs & Siren outputs.
T5
LAN connections.
JP6
Fibre Optic Port.
For future applications.
JP4
Auxiliary LAN connection. For temporary
connection of LCD Terminal for diagnostic purposes.
LED 11. On = 13V Supply present
LED 10. On = 5V Supply present.
U14.
JP3
Auxiliary Output Expansion Port.

Other manuals for Inner Range 3000