Inner Range Inception Security Controller Installation Manual. Rev. 4.0
© 2016 - 2020. Inner Range Pty Ltd. 4 www.innerrange.com
INTRODUCTION
The Inception controller is an integrated access control and intruder detection system featuring a
powerful built-in web server. No computer software is required. System configuration and
administration simply requires connecting to a network via Ethernet or Wi-Fi, and using any web
browser to navigate to Inceptions web page.
See the Quickstart Guide for connection details.
Features
USB Connection for Wi-Fi option and/or Mulitpath-IP T4000 Alarm Communicator.
Ethernet port for network connection and IP alarm communications via SkyTunnel .
Tamper input for monitoring of the external enclosure.
8 x Universal inputs for security detectors or door monitoring.
Support for a variety of Input EOL schemes.
12V DC power outputs for powering external security devices.
LAN port for system expansion via RS-485.
Reader port for connection of up to 8 x Inner Range SIFER or SIFER-Keypad readers.
DC power input for connection to the Inception power supply.
Battery connection for charging of a back-up battery.
4 x Universal relay outputs for locks, alarm sounders, strobes or automation devices.
Scan the QR code for quick setup of alarm monitoring via SkyTunnel.
Comprehensive system status LED Indicators.
‘Send All Possible Alarms’ and ‘Commissioning Report’ features to streamline
configuration of monitoring station account.
Web interface and LCD Terminal text displays can be translated into other languages.
High-level integrations with compatible 3
rd
party alarm communicator and automation
products.
NOTE: Inception Firmware. To ensure that all product features, system capacities, accessory
devices and compatible LAN expansion modules described in this manual are fully supported, check
that the Inception Controller has the latest firmware installed.

Other manuals for Inner Range inception

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inner Range inception and is the answer not in the manual?

Inner Range inception Specifications

General IconGeneral
ModelInception
CategoryController
Users10, 000
Event Log50, 000 events
Power Supply12-24V DC
Max. Readers/Doors32
Max. Users10, 000
Max. Areas64
Onboard Inputs8
NetworkEthernet
Onboard Outputs4
CommunicationEthernet, RS-485
Operating Temperature0°C to +50°C (32°F to 122°F)