a delay of 10 minutes allowing time for the Wi-Fi adapter or ethernet cable to be removed
and the cabinet secured before service mode actually ends.
Current Status: Shows the functions disabled & the service mode expiry date & time.
To Enable or Disable Service Mode.
Operation
Web Browser
LCD Terminal
Enable
Or
Update
-Open Service Mode from the Dashboard or System Menu.
-Select ‘Enable Service Mode’ or ‘Update Service Mode’.
-Choose which functions to disable and the duration.
-Click on “Enable” or “Update”.
-Logon,
-Press [MENU] [7] [1],
-Press [ON] (Enables
for 8 Hours)
Disable
-Open ‘Service Mode’ from the Dashboard or System Menu.
-Select ‘Disable Service Mode’.
-If required, choose a ‘Delay Before Disable’ period.
-Click on ‘Disable’.
-Logon,
-Press [MENU] [7] [1],
-Press [OFF]
Wireless Devices
Inception supports the Integriti Inovonics RF LAN Expander and Concept Paradox RF LAN
Expander Modules that provide an interface for RF detection devices (e.g. PIR, smoke detector,
etc), general purpose transmitters (for reed switches, etc.) and wireless remote fobs.
When RF transmitter activity is saved to the Inception review log, a signal strength value is
included in the message. This allows the installer to assess the relative signal strength of different
receiver and/or transmitter locations and the effective range of portable transmitters such as
remote fobs.
Note that the signal strength value for portable transmitters (RF fobs) is only available in the
Inception firmware release V2.0.2 or later.

Other manuals for Inner Range inception

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inner Range inception and is the answer not in the manual?

Inner Range inception Specifications

General IconGeneral
ModelInception
CategoryController
Users10, 000
Event Log50, 000 events
Power Supply12-24V DC
Max. Readers/Doors32
Max. Users10, 000
Max. Areas64
Onboard Inputs8
NetworkEthernet
Onboard Outputs4
CommunicationEthernet, RS-485
Operating Temperature0°C to +50°C (32°F to 122°F)