Inner Range Inception Security Controller Installation Manual. Rev. 4.0
© 2016 - 2020. Inner Range Pty Ltd. 6 www.innerrange.com
Accessories List
Optional Accessories
Accessory Part Number
PS Current Required
Small Enclosure with Tamper Switch
995200
N/A
Medium Enclosure with Tamper Switch
995201I
N/A
Sealed Lead Acid Battery. e.g.
12V. 7AH 18AH
CSD P/N: CSD-1200 / CSD-1217
Atlas Gentech SKU: 50204/50208
N/A
Inception USB Wi-Fi Adapter
999030
25-40mA (See
‘Specifications’ section)
Inner Range SIFER Reader V1.5.0 or
later. (V1.16.0.14 or later recommended)
994720 (Standard)
994720MF (Multi-format)
75mA to 150mA (Depends
on LED configuration)
Inner Range SIFER-Keypad Reader.
994725 (Standard)
994725MF (Multi-format)
75mA to 165mA (Depends
on LED configuration)
Inner Range OSDP<>Wiegand Converter
994200
20mA(Idle) 35mA(Peak)
T4000 Security Communicator V2.1.4 or
later.
998530LT (Lite) 998530 (Std)
120mA
T4000 - Inception interface cable.
996797
N/A
Inception USB RS232 Alarm
Communicator Interface Cable.
996798
Approx. 15mA
USB 12V Mini Hub
999032
20-40mA (See
‘Specifications’ section)
RS485 LAN/Reader Surge Diverter
995041
N/A
Integriti 3A battery-backed Power Supply
996091
N/A
Integriti 8A battery-backed Power Supply
996092
N/A
Replacement Power Supply (Australia)
999066AU
N/A
Compatible Expansion Modules
Part Number
Module f’ware
PS Current Required *
Elite LCD Terminal
995000ML
995000MLWH
Any
20mA (Idle)
45mA (In use)
EliteX Keypad
EliteX-SIFER Keypad
995400
995400SI
V3.0.13 or later.
Any
17mA (Idle) 50mA (Max)
72mA (Idle) 186mA (Max)
8-32 Zone LAN Expander Module
996005PCB&K
V3.0.1 or later
70mA (Idle)
110mA (Both Relays On)
Standard LAN Access Module (SLAM)
996012PCB&K
V4.0 or later
110mA (Idle)
175mA (Lock Relays On)
Paradox RF LAN Expander Module
995025
Any
65mA
Inovonics RF LAN Expander Module
996008
V1.1.0
115mA
UniBus 8 Zone Expander
996500PCB&K
V1.0.3 or later
75mA
UniBus 8 Relay Expander
996515PCB&K
V1.1.2 or later
45mA (Idle)
175mA (All Relays On)
UniBus 16 Floor Lift Interface Board
996540PCB&K
Any
310mA (All Relays On)
LAN Ethernet Bridge
996088PCB&K
Any
60mA
NOTES:
* Does not include current required by detectors, sounders, readers, locks, LEDs and other peripheral devices
connected to these modules.
UniBus expander boards can only be connected to an 8-32 Zone LAN Expander Module.

Other manuals for Inner Range inception

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inner Range inception and is the answer not in the manual?

Inner Range inception Specifications

General IconGeneral
ModelInception
CategoryController
Users10, 000
Event Log50, 000 events
Power Supply12-24V DC
Max. Readers/Doors32
Max. Users10, 000
Max. Areas64
Onboard Inputs8
NetworkEthernet
Onboard Outputs4
CommunicationEthernet, RS-485
Operating Temperature0°C to +50°C (32°F to 122°F)