30
Splice Option
Setting up splice mode
Select [Splice option] in menu.
Select a parameter to be changed.
5
Parameter Description
Auto Start
If “Auto Start” is set to “On”, splicing starts automatically as soon as the
windproof cover is closed. Fibers should be prepared and placed into the
splicer in advance.
Pause 1
If “Pause1” is set to “On”, splicing operation pauses when bers are
forwarded to gap-set position. Cleave angles are displayed during the
pause.
Pause 2
If “Pause2” is set to “On”, splicing operation pauses after ber alignment is
completed.
Realign After
Pause2
Alignment failure may appear after “Pause2” for a long period. Therefore,
realign after “Pause2” is needed. Setting to “OFF” will prevent the
implementation of realign function. Manual splicing, rather than setting the
realign to “OFF”, is recommended when there is an axial displacement of
the splicer.
Ignore Splicing Error
Cleave Angle
Setting to “OFF” ignores the faults and continues to complete the splicing
even if the message “Cleave Angle Error” appears.
Core Angle
Setting to “OFF” ignores the faults and continues to complete the splicing
even if the message “Core Angle Error” appears.

Table of Contents