Chapter 8 Other Functions & Utilities 43
Power save option
This function is important for power conservation. If the power saving function is
not set during battery use, the number of splice cycles will be reduced.
•
Insert a power unit, and turn on the splicer.
•
Select [Power Save Option] in [System Setting] menu.
•
Change values of [Monitor Shut Down] and [Splicer Shut Down].
System information
Select [System Information]. The following information is displayed.
Parameter Description
Monitor Shut Down Setting this function will automatically turn off the power supply to the
LCD monitor if the splicer does not operate after a certain period of
time to prevent excessive power loss. When the power supply for LCD
monitor turns off, the LED near ◎ key blinks. Press any keys to turn
on the LCD monitor.
Splicer Shut Down Setting this function will automatically turn off the power supply to the
splicer if the splicer does not operate after a certain period of time to
prevent excessive power loss.
Parameter Description
Machine Serial Number Display the serial number of the splicer.
Software Version Display the version of the software.
FPGA Display the version of FPGA.
Total Arc Count Display the total number of arc discharges.
Current Arc Count Display the number of arc discharges after electrode replacement.
Performing [Replace Electrode] resets this parameter to zero.
Last Maintenance Display the date of last maintenance.
Production Date Display the date of production.