Frequent questions and troubleshooting
Note: The solutions of common faults for reference are as follows. Please con-
tact sales agents for further support if needed.
Power does not turn off when pressing ON/OFF button.
Press and hold the key until the LED blinks, and then release the button to turn
off the splicer.
Few splices can be made with a fully charged battery pack.
Enable the power save option.
If degradation appears or the battery pack is stored for an extended period of
time, completely discharge it. And recharge the battery pack.
The battery pack has reached the end of its battery life. Change a new battery
pack.
The capacity decreases at excessive low temperature.
Error message appears on monitor.
Please refer to Appendix II.
High splice loss.
Clean the V-groove and ber holders.
Replace the electrodes.
Please refer to Appendix I.
The splice loss varies according to the cleave angle, arc conditions and ber
cleanliness.
Monitor suddenly turns off.
If the power save option is enabled, the monitor will turn off after an extended
period of splicer inactivity. Press any key to return to the normal state.
Splicer suddenly turns off.
If the power save option is enabled, the splicer will turn off after an extended
period of splicer inactivity.
Identify ber error in AUTO mode.