2.2 Environmental Specifications
Item
Working
Transportation
Storage
Environment
parameters
(IEC60721-3)
Class
IE33 IE22 IE12
Temperature
–5°C to +55°C –40°C to +70°C –25℃ to +70°C
Humidity 10% to 95%, no-condensation
Vibration
Frequency 5 Hz to 150 Hz
2M2 1M2
Displacement
3.5 mm (direct
installation) (< 9 Hz)
Acceleration
1 g (direct
installation) (> 9 Hz)
Direction 3 axial directions
Impact (collision) 15 g, 11 ms, half sine
wave, 3 axial
directions
Altitude/air pressure
0 m to 2000 m
0 m to 3000 m (> 70 kPa)
2.3 EMC Specifications
The following table provides EMC specifications of the AC700 series controller.
No. Item
Standard
Description
1
Conducted emission
Power terminals
IEC61131-2:2017
IEC 61000-6-4:2018
Class A
2
Radiated emission
Controller
IEC61131-2:2017
IEC 61000-6-4:2018
Class A
3 ESD
IEC61131-2:2017
IEC 61000-4-2:2008
±6 kV (contact discharge)
±8 kV (air discharge)
4
Radiated susceptibility (RS)
IEC61131-2:2017
IEC 61000-4-3:2006
+A1:2007+A2:2010
80 MHz to 1000 MHz 10 V/m,
1.4 GHz to 6 GHz 10 V/m
5
EFT/Burst,
DC power terminal
IEC61131-2:2017
IEC 61000-4-4:2012
±2 kV, direct injection
(5/50 ns, 5/100 kHz)
6
EFT/Burst,
Communication and signal
ports
IEC61131-2:2017
IEC 61000-4-4:2012
±2 kV, capacitive coupling
clamp
(5/50 ns, 5/100 kHz)
7
Conducted susceptibility (CS)
DC power terminal
IEC61131-2:2017
IEC 61000-4-6:2013
0.15 MHz to 230 MHz,
(1 kHz, AM 80%)
10 V, CDN
8
Conducted susceptibility (CS)
Communication and signal
ports
IEC61131-2:2017
IEC 61000-4-6:2013
0.15 MHz to 230 MHz,
(1 kHz, AM 80%)
10 V, electromagnetic clamp
9
Surge
DC power terminal
IEC61131-2:2017
IEC 61000-4-5:2014+
A1:2017
±1 kV (line to ground)
±0.5 kV (line to line)