- 29 -
Quick setup
Event Descriptions Function Drive Status
t17
Drive IGBTs got disable.
MC contactor delay OFF time active.
- Ready
t18 MC contactor de-energise after the desire set time has elapse. F8-61 Inhibit
4.2 Elevator performance 󶍾ne tuning
'SFRVFODZ%FNBOE
5JNF
4UBSU
"DDFMFSBUJPO
/PNJOBM
TQFFE
%FDFMFSBUJPO
$SFFQJOHTQFFE
4UPQ
Figure 4-2 MD500L Running S-curve
Stage Symptom Diagnostics Remedies
Start
Rollback
Brake device releases too early Increase F8-57,ranging 0 to 0.5s.
Start frequency is too low Increase F6-03, ranging 0 to1.5Hz.
Torque output is insu󶎀cient Make sure F3-00=0, F3-01=0.
Starting jerk
Brake device releases too late Decrease F8-57, ranging 0 to 0.5s.
Start frequency is too high
Decrease F6-03, ranging 0 to
1.5Hz.
Acceleration
Jerk when
acceleration
starts
Too fast acceleration at this
section
Increase F6-08, ranging 0 to 80%;
Or increase F0-17, ranging 0 to
20s.
Jerk when
acceleration
end
Too fast acceleration at this
section
Increase F6-09, ranging 0 to (95-
(F6-08))% Or increase F0-17,
ranging 0 to 20s.
Overshoot
when
acceleration
ends
Too big speed loop PI gains
Decrease F2-03, ranging 0 to 100
Or increase F2-04, ranging 0 to 10.