- 53 -
Parameter Table
7 Parameter Table
Group F0: fundamental
Parameter Parameter Name Setting Range Unit Default Commission
F0-01 Motor 1 control mode
0: Sensor-less ux vector control
(SFVC)
2: V/F control
N.A 2 -
F0-02
Command source
selection
0: Operating panel control (LED
o)
1: Terminal control (LED on)
2: Communication control (LED
ashing)
N.A 1 -
F0-03
Main frequency source
X selection
2: AI-1
3: AI-2
4: AI-3
6: Multi-reference
N.A 6 -
F0-07
Frequency source
selection
0: Main frequency source X N.A 0 -
F0-09 Rotation direction
0: Same direction
1: Reverse direction
N.A 0 -
F0-10 Maximum frequency 50.00 to 100.00 Hz 50.00 -
F0-15 Carrier frequency
0.5 to 11.0
(SVC mode: 0.5 to 9)
(V/F mode: 0.5 to 11)
kHz
Model
dependant
-
F0-17 Acceleration time 1
0.00 to 650.00 (F0-19 = 2)
0.0 to 6500.0 (F0-19 = 1)
0 to 65000 (F0-19 = 0)
s 3.0 -
F0-18 Deceleration time 1
0.00 to 650.00 (F0-19 = 2)
0.0 to 6500.0 (F0-19 = 1)
0 to 65000 (F0-19 = 0)
s 2.0 -
F0-19
Acceleration/
Deceleration time unit
0: 1
1: 0.1
2: 0.01
s 1 1