- 54 -
Parameter Table
Group F1: motor 1 parameters
Parameter Parameter Name Setting Range Unit Default Commission
F1-00 Motor type selection
0: Common asynchronous
motor
1: Variable frequency
asynchronous motor
N.A 0 -
F1-01 Rated motor power 0.1 to 1000.0 kW
Model
dependent
-
F1-02 Rated motor voltage 1 to 2000 V 400 -
F1-03 Rated motor current
0.01 to 655.35
(AC drive power ≤ 55 kW)
0.1 to 6553.5
(AC drive power > 55 kW)
A
Model
dependent
-
F1-04
Rated motor
frequency
0.01 Hz to max. frequency Hz 50 -
F1-05
Rated motor rotational
speed
1 to 65535 RPM 1440 -
F1-06
Stator resistance
(asynchronous motor)
0.001 to 65.535
(AC drive power ≤ 55 kW)
0.0001 to 6.5535
(AC drive power > 55 kW)
Ω 0 -
F1-07
Rotor resistance
(asynchronous motor)
0.001 to 65.535
(AC drive power ≤ 55 kW)
0.0001 to 6.5535
(AC drive power > 55kW)
Ω 0.000 -
F1-08
Leakage inductive
reactance
(asynchronous motor)
0.01 to 655.35mH
(AC drive power ≤ 55 kW)
0.001 to 65.535
(AC drive power > 55 kW)
mH 0.00 -
F1-09
Mutual inductive
reactance
(asynchronous motor)
0.01 to 655.35
(AC drive power ≤ 55 kW)
0.001 to 65.535
(AC drive power > 55 kW)
mH 0.00 -
F1-10
No-load current
(asynchronous motor)
0.01 to F1-03
(AC drive power ≤ 55 kW)
0.1 to F1-03
(AC drive power > 55 kW)
A 0.00 -
F1-37 Auto-tuning selection
0: No auto-tuning
2: Asynchronous motor dynamic
auto-tuning
3: Asynchronous motor static
auto-tuning (NEW)
N.A 0 -