Parameter Table
Group F7: product and software version checking
Parameter Parameter Name Setting Range Unit Default Commission
F7-08 Product number N.A N.A 380.00 display
F7-10
Performance software
version
N.A N.A - display
F7-11
Functional software
version
N.A N.A - display
F7-15
Performance software
temporary version
N.A N.A - display
F7-16
Functional software
temporary version
N.A N.A - display
Group F8: auxiliary functions
Parameter Parameter Name Setting Range Unit Default Commission
F8-04
Stop stage deceleration
time
0.0 to 6500.0 s 2.0 -
F8-26
Frequency switchover
point between
deceleration time 1 and
deceleration time 2
0.00 to max. frequency Hz 0.00 -
F8-55
Brake release current
threshold
0 to 200 % 20 -
F8-56
Brake release frequency
threshold
0.00 to 25.00 Hz 0.20 -
F8-57
Brake release delay ON
set time
0.0 to 5.0 s 0.2 -
F8-58
Brake apply frequency
threshold
0.00 to 25.00 Hz 0.20 -
F8-59
Brake apply delay OFF
set time
0.0 to 5.0 s 0.2 -
F8-60
Drive run delay ON set
time
0.20 to 10.00 s 0.20 -
F8-61
MC contactor delay OFF
set time
0.00 to 10.00 s 0.20 -
F8-62
Current threshold in UPS
mode
0.0 to 200.0 % 100.0 -
F8-63
Acceleration time in UPS
mode
0.0 to 20.0 s 3.0 -