- 63 -
Parameter Table
Parameter Parameter Name Setting Range Unit Default Commission
F8-64
Deceleration time in UPS
mode
0.0 to 20.0 s 3.0 -
F8-65
Brake apply keep
frequency set time
0.00 to 10.00 s 0.50 -
F8-66
Time proportion of
S-curve at Stop stage
start
0.0% to Min. [(100.0% - F8-67),
80%]
% 20.0 -
F8-67
Time proportion of
S-curve at Stop stage
end
0.0% to Min. [(100.0% - F8-66),
80%]
% 30.0 -
F8-68
UPS input phase mode
selection
0: Three phase UPS
1: Single-/Two-phase UPS
N.A 0 -
F8-69
Single-/Two-phase UPS
under voltage point
60.0 to 140.0 % 60.0 60% is 210V
F8-70
ON delay time for rescue
operation
0.0 to 20.0 s 0.0 -
F8-71 Regeneration load slip 50% to 200% % 100 -
F8-72 Rescue operation
0: Disable
1: Enable
N.A 0 -
F8-73
Rescue direction check
time
0.0 to 10.0 s 1.0 -
F8-75
Rescue mode under
voltage error display
0: Disable
1: Enable
N.A 0 -
F8-76
Reference speed
terminal
0: Direction
1: Speed
N.A 0 -
F8-77 Change control mode
0: Disable
1: Enable
N.A 0 -
F8-78
V/F mode multi-point
percentage
0% to 100% % 100 -
F8-79
OFF delay time for
rescue operation
0.0 to 240.0 s 0.0 -
F8-80 Short-󶍿oor function
0: Disable
1: Enable
N.A 0 -
F8-81 High frequency limit F8-82 to F0-10 Hz 40.00 -
F8-82 Low frequency limit 0.00 to F8-81 Hz 30.00 -
F8-83 Short-󶍿oor running time 0.0 to 10.0 s 4.0 -
F8-84
Short-󶍿oor frequency
delay time
0.0 to 4.0 s 0.0 -