- 121 -
ON OFF OFF OFF MS speed 8 FC-08
ON OFF OFF ON MS speed 9 FC-09
ON OFF ON OFF MS speed 10 FC-10
ON OFF ON ON MS speed 11 FC-11
ON ON OFF OFF MS speed 12 FC-12
ON ON OFF ON MS speed 13 FC-13
ON ON ON OFF MS speed 14 FC-14
ON ON ON ON MS speed 15 FC-15
NOTE: FC00 ~ FC15 the parameter corresponding unit is "Hz",
the negative number indicates reversal.
Attached Table 2 MS Speed Function Description
Terminal 2
Terminal
1
Speed-up/speed
-down time
selection
Corresponding
Parameter
OFF OFF Speed-up time 1 F0-17 and F0-18
OFF ON Speed-up time 2 F8-03, F8-04
ON OFF Speed-up time 3 F8-05 and F8-06
ON ON Speed-up time 4 F8-07 and F8-08
Reserved
Factory default
value
-
F4-05~
F4-14
Setup
range
-
DI filter time
Factory default
value
4
F4-15
Setup
range
0~10
It is used to set the sensitivity of DI terminal. If the digital input terminal is
vulnerable to interferences and may cause error action, it can increase this
parameter value to enhance the anti-interference capability. However, this
operation will reduce the sensitivity of DI terminal.
Terminal
command mode
Factory default
value
0
0
Two-line mode 1
1 Two-line mode 2
F4-16
Setup
range
2 Three-line mode 1