MD021 Plastic Wire Drawing Machine User Manual
Figure 3-1 Indicators on the operation panel and wiring digram
Data
RUN/ERR
ON
OFF
Power
T/A
T/B
T/C
+12 V
DO
+ 5 V
AI
GND
DI2
DI1
GND
U
V
W
L
N
PE
3.2.1 Descriptions of Indicators on the Operation Panel
DATA: This indicator blinks when data is received.
RUN/ERR: This indicator stays on when the inverter is running, and
blinks when a fault occurs. You can set the indicator to another
function by modifying the function of the DO terminal.
POWER: This indicator is on when the power button is pressed and
the power supply is normal. If the indicator becomes off, it indicates
that the power supply is abnormal or a fault occurs. If the indicator
blinks, it indicates that the wiring of the control circuit may be
abnormal, triggering protection to the inverter.