MD021 Plastic Wire Drawing Machine User Manual 
 
state, the  terminal  outputs  the  ON 
signal. 
When a wire-break fault occurs on 
the  inverter,  the  terminal  outputs 
the ON signal. 
When  a  fault  occurs  on  the 
inverter,  the  terminal  outputs  the 
ON signal. 
 
Note:  The  DO  terminal is  connected  to  an  indicator  to  indicate the 
running  status.  If  "DO  output  selection"  (F1-09)  is  set  to  2 
(Wire-break fault output) or 3 (Fault output), the indicator blinks (the 
DO terminal outputs pulse signals with an interval of 400 ms) when a 
corresponding  fault  occurs;  the  indicator  is  off  (the  DO  terminal 
outputs low level) when the inverter stops without fault; the indicator 
is  on  (the DO  terminal  outputs  high  level)  when  the  inverter  is  in 
running state. 
 
Group  F2:  Functions  and  Faults  of  Wire  Drawing 
Machine 
PID  control  is  a  general  method  of  process  control.  It  adjusts  the 
output  frequency  of  the  inverter  through  proportional,  integral  and 
differential calculations of the difference between the feedback signal 
and the target signal and constitutes a feedback system to stabilize the