Chapter 6 Description of Function Codes 
Group F0: Basic Function Parameters 
0: Operation panel 
1: Terminal input 
2:  Via 
communication 
 
This  parameter  specifies  the  input  channel  of  inverter  control 
commands, such as start,  stop, forward run (FWD), and reverse run 
(REV). 
0: Operation panel (the LOCAL/REMOT indicator is off.) 
Commands are given by pressing keys RUN and STOP/RES on the 
operation panel. 
1: Terminal input (the LOCAL/REMOT indicator is on.) 
Commands  are  given  using  multi-function  input  terminals  such  as 
FWD and REV. 
2: Serial port communication (the LOCAL/REMOT indicator blinks.) 
Commands  are  given  by  the  host  computer.  For  details  on  the 
communication  protocol,  see  "Modbus  Serial  Communication 
Protocol for the Plastic Wire Drawing Machine."