Loading...
MD021 Plastic Wire Drawing Machine User Manual
Chapter 6 Description of Function Codes
Group F0: Basic Function Parameters
Function Code
Name
Range
Default
F0-00
Command
source
selection
0: Operation panel
1: Terminal input
2: Via
communication
1
This parameter specifies the input channel of inverter control
commands, such as start, stop, forward run (FWD), and reverse run
(REV).
0: Operation panel (the LOCAL/REMOT indicator is off.)
Commands are given by pressing keys RUN and STOP/RES on the
operation panel.
1: Terminal input (the LOCAL/REMOT indicator is on.)
Commands are given using multi-function input terminals such as
FWD and REV.
2: Serial port communication (the LOCAL/REMOT indicator blinks.)
Commands are given by the host computer. For details on the
communication protocol, see "Modbus Serial Communication
Protocol for the Plastic Wire Drawing Machine."