EasyManua.ls Logo

Inovance MD021 - F2-00 and F2-01 PID Settings

Inovance MD021
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MD021 Plastic Wire Drawing Machine User Manual
F0-01
Frequency
source
selection
0: Digital setting
1: Special wrap-up mode
for wire drawing machine
2: AI
3: PID
4: Via communication
1
This parameter specifies the input channel of the inverter frequency. A
total of five input channels are available:
0: Digital setting
The initial value is the value set in the parameter "Preset frequency"
(F0-03).
1: Special wrap-up mode for wire drawing machine
The frequency obtained by superposition of the frequency set via
communication (or set on the operation panel) and PID frequency is
used as the running frequency of the inverter. For details on how to set
the frequency via communication, see "Modbus Serial
Communication Protocol for the Plastic Wire Drawing Machine." For
the meaning of the PID setting source, PID setting and feedback range,
and PID feedback, see Group F2 function codes. In addition, you can
change the method from "frequency set via communication + PID" to
"frequency set by operation panel + PID"; for details, see the
descriptions of F2-09 and F2-10.
2: AI
The frequency is given by the analog input terminal, which provides 0
V to 5 V voltage input. For the corresponding setting of AI input

Related product manuals