MD021 Plastic Wire Drawing Machine User Manual
Voltage
F1-01
0.0%
F1-03
0 V
F1-04 F1-06
AI
Corresponding value
(such as frequency)
Function Code
Name
Default
F1-08
Relay output selection
3: Fault output
F1-09
DO output selection
3: Fault output
The parameter in F1-08 specifies the functions of the relay output
terminals TA, TB, and TC. TA is the common terminal of the relay;
TB is a normally closed (NC) output terminal, and TC is a normally
open (NC) output terminal.
The functions that can be selected for the output terminals are as
follows:
Value
Function
Description
0
No output
The output terminal has no
function.
1
Inverter
When the inverter is in running