MD021 Plastic Wire Drawing Machine User Manual
Function
Code
Name
Range
Min.
Unit
Default
Property
F0-08
Motor rated
current
0.1 A to
6553.5 A
0.1 A
Depend
on the
motor
power
★
F0-09
Motor rated
frequency
0.01 Hz to
maximum
frequency
(F0-02)
0.01
Hz
Depend
on the
motor
model
★
F0-10
Torque
boost
0.0% to 30.0%
0.1%
15.0%
☆
F0-11
Cutoff
frequency
of torque
boost
0.01 Hz to
maximum
frequency
(F0-02)
0.01
Hz
100.00
Hz
★
F0-12
Software
version 1
-
-
-
●
F0-13
Software
version 2
-
-
-
●