EasyManua.ls Logo

Inovance MD021 - F0-03 to F0-05 Parameters

Inovance MD021
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MD021 Plastic Wire Drawing Machine User Manual
Function
Code
Name
Range
Min.
Unit
Default
Property
F0-08
Motor rated
current
0.1 A to
6553.5 A
0.1 A
Depend
on the
motor
power
F0-09
Motor rated
frequency
0.01 Hz to
maximum
frequency
(F0-02)
0.01
Hz
Depend
on the
motor
model
F0-10
Torque
boost
0.0% to 30.0%
0.1%
15.0%
F0-11
Cutoff
frequency
of torque
boost
0.01 Hz to
maximum
frequency
(F0-02)
0.01
Hz
100.00
Hz
F0-12
Software
version 1
-
-
-
F0-13
Software
version 2
-
-
-

Related product manuals