MD021 Plastic Wire Drawing Machine User Manual
Function Code
Name
Range
Default
F2-01
PID digital
setting
0.0% to
100.0%
50.0%
This parameter needs to be set when F2-00 is set to 0. This parameter
is set on the operation panel.
The base value of this parameter is the feedback value of the system.
Function
Code
Name
Range
Default
F2-02
PID setting and
feedback range
0 to 65535
1000
This parameter is a non-dimensional unit, and is used for PID setting
display and PID feedback display.
For example, when this parameter is set to 1000, 0% to 100% of the
PID setting value corresponds to 0 to 1000 in a linear mode.
Function
Code
Name
Range
Default
F2-03
Proportional gain P
0.1 to 100.0
8.5
F2-04
Integral time I
0.01s to 10.00s
0.40s
Proportional gain P: It decides the regulating intensity of the PID
regulator. The larger P is, the greater the regulating intensity is. If it is