EasyManua.ls Logo

Inovance MD021 - Page 50

Inovance MD021
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MD021 Plastic Wire Drawing Machine User Manual
set to 100, indicating that the deviation of PID feedback and PID
setting is 100%, the regulating amplitude required by the PID
regulator on the output frequency command is maximum frequency
(ignoring the integration and differential effects).
Integration time I: It decides the time of integral regulating on PID
feedback and PID setting. When the deviation of PID feedback and
PID setting is 100%, the integral regulator performs continuous
regulation during the time. Then the regulating amplitude reaches the
maximum frequency set in F0-02. The shorter the integral time is, the
greater the regulating intensity is.
Function
Code
Name
Range
Default
F2-05
PID upper limit
0% to 100%
2%
This parameter specifies the frequency upper limit of PID regulation.
This parameter is set based on a percentage of the maximum
frequency.
Function
Code
Name
Range
Default
F2-06
Lower limit for
wire-break detection
0% to 50%
5%
F2-07
Judging delay time of
wire-break detection
0s to 50s
3s

Related product manuals