MD021 Plastic Wire Drawing Machine User Manual
operation panel
maximum
frequency
(F0-02)
When "Frequency source selection" (F0-01) is set to 1 (Special
wrap-up mode for wire drawing machine), the running frequency of
the wire drawing machine can be given by "frequency set via
communication + PID" or "F2-10 + PID".
If F2-09 is set to 0 (Not enable), the running frequency of the wire
drawing machine is given by "frequency set via communication +
PID".
If F2-09 is set to 1 (Enable), the running frequency of the wire
drawing machine is given by "F2-10 + PID".
F2-11
Type of first fault
0 to 18
-
F2-12
Type of second fault
-
F2-13
Type of latest fault
The three parameters record the types of the latest three faults. 0
indicates that no fault occurs, and the values 1-18 correspond to Err01
to Err18 respectively.
F2-14
Frequency on
fault
Display the frequency
when the latest fault
occurs.
-