Description of Function Codes
MD280 User Manual
- 142 -
details, see the output terminal functions described in group F3.
:KHQ)LVVHWWR 0XOWLUHIHUHQFHVHW)DQG)WRGHWHUPLQHWKHUHTXLUHG
speeds.
Function Code Parameter Name Setting Range Default
F8-00
Reference 0 setting
source
0: Set by F8-01
1: AI1
2: AI2
3: Pulse setting
4: PID
3UHVHWIUHTXHQF\)ZLWK
83'2:1PRGL¿FDWLRQ
0
It is used to set the setting source of reference 0.
1RWHWKDWZKHQ)LV VHWWR)3,'VHWWLQJVRXUFH FDQQRWEHVHWWR0XOWL
UHIHUHQFH
Function Code Parameter Name Setting Range Default
F8-01 Reference 0
-100.0%–100.0% 0.0%
F8-02 Reference 1
-100.0%–100.0% 0.0%
F8-03 Reference 2
-100.0%–100.0% 0.0%
F8-04 Reference 3
-100.0%–100.0% 0.0%
F8-05 Reference 4
-100.0%–100.0% 0.0%
F8-06 Reference 5
-100.0%–100.0% 0.0%
F8-07 Reference 6
-100.0%–100.0% 0.0%
F8-08 Reference 7
-100.0%–100.0% 0.0%
:KHQ)LVVHWWR3/&\RXQHHGWRVHWWKH3/&UXQQLQJSDUDPHWHUV)WR)
The negative/positive mark of values of F8-00 to F8-08 determines the simple PLC running
direction: The positive mark indicates the forward direction, and the negative mark indicates
the reverse direction.
Figure 6-23 Simple PLC running
F8-01
Simple PLC running
F8-03
F8-07
F8-08
Acceleration
/Deceleration
time defined in
F8-13
Acceleration
/Deceleration
time defined in
F8-15
F8-02
Acceleration
/Deceleration
time defined in
F8-17
F8-12
F8-14
250 ms
pulse signal
DO, relay