MD280 User Manual Operation and Display
- 55 -
)LJXUH([DPSOHRIFKDQJLQJWKHSDUDPHWHUYDOXH
50.00 F0 F1 F1-00 F1-06
F1 F1-07 015.00 010.00 010.00
PRG Ƹ
Enter
Ƹ
Ƹ
Enter
Ƹ
PRG
PRG
Enter
In Level III menu, if the parameter has no blinking digit, it means that the parameter cannot
EHPRGL¿HG7KLVPD\EHEHFDXVH
Such a function code is only readable, such as, AC drive model, actually detected
parameter and running record parameter.
6XFKDIXQFWLRQFRGHFDQQRWEHPRGL¿HGLQWKHUXQQLQJVWDWHDQGFDQRQO\EHFKDQJHG
at stop.
In the function code display state, select the required function code pressing
or .
4.3 Viewing Status Parameters
In the stop or running state, you can press on the operation panel to display status
parameters. Whether parameters are displayed is determined by the binary bits of values
FRQYHUWHGIURPWKHYDOXHVRI)DQG)LQWKHKH[DGHFLPDOIRUPDW
In running state, a total of 16 running status parameters can be displayed by default, set in
F7-13, as listed in the following table.
Function
Code
Parameter
Name
Setting Range Default
F7-13
LED display
running
parameters
1-65535
7 6 5 4 3 2 1 0
DO state
Output voltage V
DI state
Running frequency Hz
Bus voltage V
Output current A
Output power kW
Set frequency Hz
15 14 12 11 10 9 8
AI2 voltage V
PID setting
AI1 voltage V
PID feedback
13
Counted value
Pulse frequency Hz
Speed display
Length value
799
In stop state, a total of eight status parameters can be displayed, as listed in the following
table.