Description of Function Codes
MD280 User Manual
- 150 -
Function Code Parameter Name Setting Range Default
FC-06 Torque boost
0.0%–30.0%
)L[HG
1.0%
See the description of F1-05.
Function Code Parameter Name Setting Range Default
FC-07 6OLSFRPSHQVDWLRQFRHI¿FLHQW 0%–200.0% 0.0%
See the description of F1-13.
Function Code Parameter Name Setting Range Default
FC-08 Oscillation suppression gain 0–100 Model dependent
See the description of F1-17.
Function Code Parameter Name Setting Range Default
FC-09
Motor 2 acceleration/
deceleration time
0: Same as motor 1
1: Acceleration/Deceleration
WLPH)DQG)
2: Acceleration/Deceleration
WLPH)DQG)
0
Group FD: AI Correction
Function Code Parameter Name Setting Range Default
FD-00 AI1 measured voltage 1 0.50–4.00 V Factory-corrected
FD-01 AI1 sampled voltage 1 0.50–4.00 V Factory-corrected
FD-02 AI1 measured voltage 2 6.00–9.99 V Factory-corrected
FD-03 AI1 sampled voltage 2 6.00–9.99 V Factory-corrected
FD-04 AI2 measured voltage 1 0.50–4.00 V Factory-corrected
FD-05 AI2 sampled voltage 1 0.50–4.00 V Factory-corrected
FD-06 AI2 measured voltage 2 6.00–9.99 V Factory-corrected
FD-07 AI2 sampled voltage 2 6.00–9.99 V Factory-corrected
These parameters are used to correct the AI to eliminate the impact of AI zero offset and
gain.
The on-site correction is as follows:
1. Modify these parameters to the default setting manually or directly restore all default
settings by setting FP-01.
2. 6HQGDYROWDJHVLJQDODSSUR[LPDWHO\9WR$,0HDVXUHWKH$,YROWDJHDQGYLHZWKH
displayed sampled value.
3. 6HQGD YROWDJHVLJQDODSSUR[LPDWHO\9WR$,0HDVXUH$, YROWDJHDQG YLHZWKH
displayed sampled value.
efesotomasyon.com