MD280 User Manual                                                                                                         Troubleshooting 
- 161 -
Current detection 
fault
Err18
1. The HALL device is faulty.
2. The drive board is faulty.
1. Replace the faulty HALL 
device.
2. Replace the faulty drive 
board.
Motor auto-
tuning fault
Err19
1. The motor parameters are not 
set according to the nameplate.
2. The motor auto-tuning times 
out.
1. Set the motor parameters 
according to the nameplate 
properly. 
2. Check the cable connecting 
the AC drive and the motor.
EEPROM read-
write fault
Err21
1. The EEPROM chip is 
damaged.
Replace the main control 
board.
Short circuit to 
ground
Err23
The motor is short circuited to the 
ground.
Replace the cable or motor.
Accumulative 
running time 
reached
Err26
The accumulative running time 
reaches the setting value.
Clear the record through 
the parameter initialization 
function.
Software 
overcurrent
Err31 -
See the description of F5-25 
6RIWZDUHRYHUFXUUHQW
Fast current limit 
timeout
Err40
1. The acceleration/deceleration 
time is too short.
2. Manual torque boost or V/F 
curve is not appropriate.
3. The startup operation is 
performed on the rotating motor.
6. The load is too heavy.
2. Increase the acceleration/
deceleration time.
3. Adjust the manual torque 
boost or V/F curve.
4. Use rotational speed 
tracking startup or perform 
startup after the motor stops.
5. Use an AC drive of a higher 
power class.
Motor switchover 
fault during 
running
Err41
Motor switchover is performed 
via terminal during running of the 
AC drive.
Perform motor switchover after 
the AC drive stops.
Motor overheat Err45
1. The cabling of the temperature 
sensor becomes loose.
2. The motor temperature is too 
high.
1. Check the temperature 
sensor cabling and eliminate 
the cabling fault.
2. Lower the carrier frequency 
or adopt other heat radiation 
measures. 
Initial position 
fault
Err51
The motor parameters are not 
set based on the actual situation.
Check whether the motor 
parameters are set correctly 
and whether the setting of 
rated current is too small.
 
efesotomasyon.com