EasyManua.ls Logo

Inovance MD280NT2.2GB - Page 164

Inovance MD280NT2.2GB
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MD280 User Manual Troubleshooting
- 163 -
SN Fault Possible Causes Solutions
6
The DI terminals
are disabled.
1. The parameters are set
incorrectly.
2. Cable connection is incorrect.
4. The control board is faulty.
1. Check and set related
parameters correctly.
5HFRQQHFWWKHH[WHUQDO
signal cables.
3. Contact the agent or
Inovance for technical
support.
7
The AC
drive reports
overcurrent and
overvoltage
frequently.
1. The motor parameters are set
improperly.
2. The acceleration/deceleration
time is improper.
7KHORDGÀXFWXDWHV
1. Set the motor parameters
in group F1 again.
2. Set proper acceleration/
deceleration time.
3. Contact the agent or
Inovance for technical
support.
efesotomasyon.com

Table of Contents

Related product manuals