Chapter 3 Mechanical and Electrical Installation
-27-
3.2 Electrical Installation
1. Prototyping guidance to the peripheral electrical components:
Table 3-1 Guide to Prototyping of Peripheral Electrical Components of MD300 Inverter
Inverter
model
Circuit
breaker
(MCCB)
˄
A
˅
Recom
mended
Contact
or (A)
Recommen
ded
Conducting
Wire of
Main Circuit
at the Input
Side (mm)
Recommen
ded
Conducting
Wire of
Main Circuit
at the
Output Side
(mm)
Recomme
nded
Conducti
ng Wire of
Control
Circuit
(mm)
Grounding
cables
˄
mm²
˅
MD300S0.4 16 10 2.5 2.5 1 2.5
MD300S0.7 16 10 2.5 2.5 1 2.5
MD300S1.5 20 16 4 2.5 1 2.5
MD300S2.2 32 20 6 4 1 2.5
MD300T0.7 10 10 2.5 2.5 1 2.5
MD300T1.5 16 10 2.5 2.5 1 2.5
MD300T2.2 16 10 2.5 2.5 1 2.5
MD300T3.7 25 16 4 4 1 4
MD300T5.5 32 25 4 4 1 4
MD300T7.5 40 32 4 4 1 4
MD300T11 63 40 4 4 1 4
MD300T15 63 40 6 6 1 6
MD300T18.5 100 63 6 6 1 6
MD300T22 100 63 10 10 1 10
MD300T30 125 100 16 10 1 10
MD300T37 160 100 16 16 1 16
MD300T45 200 125 25 25 1 16
MD300T55 200 125 25 25 1 16
MD300T75 250 160 35 35 1 16
MD300T90 250 160 35 35 1 16
2. Use instruction of peripheral electrical components: