Chapter 5 Function Parameter Table
-41-
Chapter 5 Function Parameter Table
If FP-00 is set to non-zero value, it means parameter protection password is set, and the
parameter menu cannot be opened until correct password is entered. To cancel the password,
it needs to set FP-00 to “0”.
The symbols of the function code are described as follows:
ż”: It indicates that the parameter setup value can be modified when the
inverter is in stop status and running status.
×”: It indicates that the parameter setup value cannot be modified when the inverter is in
the running status.
“*”it indicates the parameter is the actual tested value, which cannot be modified.
”: It indicates this parameter is “Factory default parameter” and can be set only by the
manufacturer.
Function Parameter Table
Code Name Setup range
Minimum
unit
Factory
default
value
Cha-
nge
Group F0 Basic Function Group
F0-00 Control mode
0: None-speed sensor vector
control (SVC)
1: Reserved
2: V/F control
1 0 ×
F0-01
Command Source
Selection
0: Operation panel running
command channel (LED OFF)
1: terminal operation command
channel (LED ON)
1 0 ż
F0-02
Frequency source
selection
0: Digital setup (without
memory)
1: Digital setup (with memory)
2: Pulse setup (effective DI4
input )
3: Al1
4: Al2
5: MS speed
1 0 ×