Chapter 6 Parameter Description   
 
-53- 
 
Chapter 6 Parameter Description 
Group F0 Basic parameters
Control
mode 
Factory default 
value 
0
0 
Non-speed sensor 
vector control 
1 
Reserved 
F0-00 
Setup 
range 
2 
V/F control 
0: None-speed sensor vector control (SVC) 
refers to open-loop vector. 
It is applicable to the general 
high-performance control applications where 
one inverter can only drive one motor.   The 
examples include machine tool, centrifugal 
machine, wire drawing machine and injection 
molding machine.   
V/F control 
It is applicable to the site with low 
requirement for control precision, such as fan, 
pump load.    It can be used in the applications 
where one inverter drives multiple motors.   
Prompt: Motor parameter identification must 
be conducted when selecting the vector 
control mode.  Refer to4.5 for details. 
Command
Source 
Selection 
Factory 
default 
value 
0 
0 
Operation panel 
command channel 
(LED OFF) 
F0-01 
Setup 
range 
1 
Terminal command 
channel (LED ON) 
Select the channel for inverter control 
command.   
The inverter control command includes start, 
stop, forward rotation, reverse rotation and 
Jog.   
0 Keypad control (“LOCAL/REMOT” LED 
OFF) 
Perform running command control with keys 
on the keypad panel, such as RUN, 
STOP/RES keys. If set multi-functional key 
MF.K to FWD/REV switching function (set 
F6-11 to 2), the running direction can be 
changed by pressing the key.
 
1: Terminal control (“LOCAL/REMOT” LED 
ON) 
Perform running command control by the 
multifunctional input terminals such as FWD, 
REV, JOGF, JOGR, etc. 
Main frequency 
source X 
selection 
Factory 
default 
value 
0 
0
Digital setup UP 
and DOWN 
(without memory)   
1
Digital setup UP 
and DOWN (with 
memory)   
2
2: Pulse setup 
(effective DI4 
input ) 
3AI1 
4
AI2 
F0-02
Setup 
range 
5
MS speed 
Select the input channel for main reference 
 