Chapter 6 Parameter Description   
 
-72- 
 
remote operation.  It refers to switching of 
command source, switching from the current 
command source to the keyboard control 
(local operation).  If the current command 
source is keyboard control, this command is 
disabled.   
2: Switching between forward rotation and 
reverse rotation 
It can switch the direction of the frequency 
command via the MF.K key on the keyboard.  
It is enabled only in the operation panel 
command channel.   
3: Forward rotation Jog   
It can realize forward rotation Jog (FJOG) via 
the MF.K key on the keyboard.   
STOP/RESET
key function 
Factory 
default 
value 
0 
0 
STOP key disabled 
in the terminal 
control mode 
F6-12 
Setup 
range 
1 
STOP key enabled 
in the terminal 
control mode 
The RESET function is enabled in all 
statuses.  
Earth short 
circuit 
protection 
detection 
upon 
power-on 
Factory 
default 
value 
1 
F6-13 
Setup 
range 
0: Disabled 
1: Enabled 
It can select whether the inverter checks the 
motor for earth short circuit failure upon 
power-on.  If this function is enabled, the 
inverter has short-time output at the instance 
of power-on.   
MS
speed 0
Factory 
default value 
0.0 
Hz 
F6-14
Setup 
range 
Negative maximum 
frequency to 
maximum frequency 
MS
speed 1
Factory 
default value 
0.0
Hz 
F6-15
Setup 
range 
Negative maximum 
frequency to 
maximum frequency 
MS
speed 2
Factory 
default value 
0.0
Hz 
F6-16
Setup 
range 
Negative maximum 
frequency to 
maximum frequency 
MS
speed 3
Factory 
default value 
0.0
Hz 
F6-17
Setup 
range 
Negative maximum 
frequency to 
maximum frequency 
When selecting MS speed as frequency 
source (F0-02=5), it is required to set the 
value from F6-14 to F6-17. 
heatsink 
temperat
ure 
Factory 
default 
value 
1ć 
F6-18
Setup 
range 
0ć
150ć 
Display 
heatsink 
temperature 
F6-19
Software 
version 
No. 
Factory 
default 
value 
Version 
No. of 
current 
software 
 