EasyManua.ls Logo

Inovance MD300 Series - Page 79

Inovance MD300 Series
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 EMC (Electromagnetic Compatibility)
-77-
installing cabinet in large area and
have good conduction continuity.
Otherwise there may be danger of
electric shock and the EMC effect
may be greatly affected.
3ǃ Through the EMC test, it is found that
the filter ground must be connected
with the PE end of the inverter at the
same public earth. Otherwise the
EMC effect may be greatly affected.
4ǃ The filter shall be installed at a place
close to the input end of the power
supply as much as possible.
5ǃ The input wire of the filter shall not
close to the output wire.
efesotomasyon.com

Related product manuals