Technical Data
‑158‑
Item
Technical specifications
Control
perform
ance
Asyn
chro
nous
motor
(SVC)
Supported
function
Energy saving control, inertia auto‑tuning, acceleration
feedforward, droop control, master‑slave control, free
programming and self‑adaption of speed loop
parameters, load observer, overvoltage suppression,
voltage dip suppression, overexcitation fast
deceleration, automatic voltage adjustment (AVR
generator bus voltage control), flying start, DC braking,
continuous operation after smooth switchover to SVC
upon encoder abnormality, and FVC‑to‑SVC switchover
at designated frequency (This can avoid abnormal
operation caused by high‑speed jitter of the encoder.)
Speed
regulation
range
1: 500
Starting
torque
200%
Speed step
response
Within 2 ms
Torque
control
accuracy
±3% when the torque is above 5 Hz
Speed
stability
accuracy
Within 10% of the rated slip value
Flux
weakening
magnifica
tion
5